521 research outputs found

    Experimental Demonstration of Time-Delay Interferometry for the Laser Interferometer Space Antenna

    Full text link
    We report on the first demonstration of time-delay interferometry (TDI) for LISA, the Laser Interferometer Space Antenna. TDI was implemented in a laboratory experiment designed to mimic the noise couplings that will occur in LISA. TDI suppressed laser frequency noise by approximately 10^9 and clock phase noise by 6x10^4, recovering the intrinsic displacement noise floor of our laboratory test bed. This removal of laser frequency noise and clock phase noise in post-processing marks the first experimental validation of the LISA measurement scheme.Comment: 4 pages, 4 figures, to appear in Physical Review Letters end of May 201

    Digitally enhanced homodyne interferometry

    Get PDF

    The Effects of Orbital Motion on LISA Time Delay Interferometry

    Full text link
    In an effort to eliminate laser phase noise in laser interferometer spaceborne gravitational wave detectors, several combinations of signals have been found that allow the laser noise to be canceled out while gravitational wave signals remain. This process is called time delay interferometry (TDI). In the papers that defined the TDI variables, their performance was evaluated in the limit that the gravitational wave detector is fixed in space. However, the performance depends on certain symmetries in the armlengths that are available if the detector is fixed in space, but that will be broken in the actual rotating and flexing configuration produced by the LISA orbits. In this paper we investigate the performance of these TDI variables for the real LISA orbits. First, addressing the effects of rotation, we verify Daniel Shaddock's result that the Sagnac variables will not cancel out the laser phase noise, and we also find the same result for the symmetric Sagnac variable. The loss of the latter variable would be particularly unfortunate since this variable also cancels out gravitational wave signal, allowing instrument noise in the detector to be isolated and measured. Fortunately, we have found a set of more complicated TDI variables, which we call Delta-Sagnac variables, one of which accomplishes the same goal as the symmetric Sagnac variable to good accuracy. Finally, however, as we investigate the effects of the flexing of the detector arms due to non-circular orbital motion, we show that all variables, including the interferometer variables, which survive the rotation-induced loss of direction symmetry, will not completely cancel laser phase noise when the armlengths are changing with time. This unavoidable problem will place a stringent requirement on laser stability of 5 Hz per root Hz.Comment: 12 pages, 2 figure

    Time Domain Simulations of Arm Locking in LISA

    Get PDF
    Arm locking is a technique that has been proposed for reducing laser frequency fluctuations in the Laser Interferometer Space Antenna (LISA), a gravitational-wave observatory sensitive in the milliHertz frequency band. Arm locking takes advantage of the geometric stability of the triangular constellation of three spacecraft that comprise LISA to provide a frequency reference with a stability in the LISA measurement band that exceeds that available from a standard reference such as an optical cavity or molecular absorption line. We have implemented a time-domain simulation of arm locking including the expected limiting noise sources (shot noise, clock noise, spacecraft jitter noise, and residual laser frequency noise). The effect of imperfect a priori knowledge of the LISA heterodyne frequencies and the associated 'pulling' of an arm locked laser is included. We find that our implementation meets requirements both on the noise and dynamic range of the laser frequency.Comment: Revised to address reviewer comments. Accepted by Phys. Rev.

    Stabilization of injection-locked lasers using spatial mode interference

    Get PDF
    We report the use of spatial-mode-interference, or tilt-locking, for the active stabilization of injection-locking of a Nd:YAG laser. We show that this control scheme is robust and adds negligible frequency noise to the injection-locked laserOttaway, D.J.; Gray, M.B.; Shaddock, D.A.; Hollitt, C.; Veitch, P.J.; Munch, J.; McClelland, David Ernes

    Searching for Gravitational Waves with a Geostationary Interferometer

    Full text link
    We analyze the sensitivities of a geostationary gravitational wave interferometer mission operating in the sub-Hertz band. Because of its smaller armlength, in the lower part of its accessible frequency band (10−4−2×10−210^{-4} - 2 \times 10^{-2} Hz) our proposed Earth-orbiting detector will be less sensitive, by a factor of about seventy, than the Laser Interferometer Space Antenna (LISA) mission. In the higher part of its band instead (2×10−2−102 \times 10^{-2} - 10 Hz), our proposed interferometer will have the capability of observing super-massive black holes (SMBHs) with masses smaller than ∼106\sim 10^{6} M⊙_{\odot}. With good event rates for these systems, a geostationary interferometer will be able to accurately probe the astrophysical scenarios that account for their formation.Comment: 33 pages, 9 eps figure

    Measuring coalignment of retroreflectors with large lateral incoming-outgoing beam offset

    Get PDF
    A method based on phase-shifting Fizeau interferometry is presented with which retroreflectors with large incoming-outgoing beam separations can be tested. The method relies on a flat Reference Bar that is used to align two auxiliary mirrors parallel to each other to extend the aperture of the interferometer. The method is applied to measure the beam coalignment of a prototype Triple Mirror Assembly of the GRACE Follow-On Laser Ranging Interferometer, a future satellite-to-satellite tracking device for Earth gravimetry. The Triple Mirror Assembly features a lateral beam offset of incoming and outgoing beam of 600 mm, whereas the acceptance angle for the incoming beam is only about ±2 mrad. With the developed method, the beam coalignment of the prototype Triple Mirror Assembly was measured to be 9 μrad with a repeatability of below 1 μrad

    Progress in Interferometry for LISA at JPL

    Full text link
    Recent advances at JPL in experimentation and design for LISA interferometry include the demonstration of Time Delay Interferometry using electronically separated end stations, a new arm-locking design with improved gain and stability, and progress in flight readiness of digital and analog electronics for phase measurements.Comment: 11 pages, 9 figures, LISA 8 Symposium, Stanford University, 201
    • …
    corecore